*119956*
Agriculture / 4.
Technologies of storage and processing of agricultural products
PhD Romanenko O.V.
PhD Donchevska R.S.
PhD Romanenko R.P.
Kyiv National University of Trade and Economics,
Ukraine
Determination of jellied fish products optical properties
Sensory methods are the most common for optical
properties of jellied products evaluation. However, these are based on the
primary subjective perception of smell, taste, sight, touch sensations.
Therefore, to improve the objectivity and to provide the possibility of not
only finished products but also semi-prepared foods evaluation we need to use
semi-optical methods.
Transparency or turbidity indicator of jellied food
products can be determined according to its environment ability to disperse and
reduce light flux rate, this process is aimed to evaluate quality rate and the
possibility of jellied food products storage. In linear optics this indicator is called environment
transparency.
Colloidal solutions, emulsions, suspensions
transparency can be identified in transmitted light, it means that the sample
should be contained between light source and receiver. Transparency is usually determined using monochromatic light sources or
light rays with a wide range of frequencies, the most accurate results can be
obtained using the monochromatic source. With emission frequency decreasing
(increasing wavelength) transparency increases, therefore determination of this
indicator is recommended to be held using light with the larges visible
wavelength – red spectrum light.
As we know the basic quantitative methods of turbidity
determination are described in DSTU ISO 7027:2003 (State standard of Ukraine ISO)
“National Standard of Ukraine: water quality. Determination of turbidity”. The indicator of
turbidity can also be determined by turbidimeter. Scope of this method is
wider, but the factors of peculiarities associated with turbidimeter
calibration features, where the reflection / absorption coefficient
of cuvette optical glass is engaged and adjustment for heterogeneity
geometrical dimensions of the sample are absent makes determination of jellied
fish products turbidity impossible.
Developed method allows to determine gelatinous
structures turbidity due to taking
into account the heterogeneity of the samples geometrical dimensions and the
reflection coefficient of jellied product by itself, not the glass
reflection / absorption coefficient. Jellied product transparency
determining unit (figure 1) is much simpler than the others equipment for the
determination of optical parameters of the products.
Figure
1. Diagram of jellied product transparency determining unit
"Universal guage ITM" that consists of
electronic units, a set of sensors and software to interface with the Windows
OS is used in this device for high-frequency fixation of luxmeter values.
Laboratory monochrome gas discharge laser emitter ESPE-11 with a 660 nm
wavelength is used as a source of radiation.
In Figure 2 the photos of the cuvette with tested sample during the laser ray without the diffraction grating (one beam)
passing through are represented. The photos of samples were took in dark
without using the flash.
|
|
Figure
2. Photos of cuvette with the studied samples during the laser beam passing
through. Left image is
inverted. |
Advantages of suggested method are connected with the
fact that, firstly, possibility to determine the turbidity of broth at a
certain depth appears, secondly, coherent monochromatic waves with length 660
nm which extend the boundaries of turbidity measuring are applied.
Basic in the claimed invention is the goal to improve
methods of gelatinous food products, particular structure-based food broths,
quality assessment.
In the case when the radius of the base of the cone
scattering laser beam is smaller than the Illuminometers sensor (luxmeters)
radius, light flow intensity can be defined by the next formula:
(1)
where: I –
is light
flow intensity, Lm; J
– is the level of Illuminometers sensor (luxmeters) lightning, LH; R - radius of the base of the scattering
laser beam cone, mm; r -
Illuminometers sensor radius, mm.
Light flow extinction coefficient can be
defined by the next formula:
;
(2)
where: k –
is extinction coefficient, mm-1; I0 - intensity of the light
flow in the chamber without turned on laser, Lm; I1 – is turned on lasers light flow
intensity, Lm; Isample – the
intensity of light flow after passing the sample, Lm; lsample - samples thickness, mm.
Jellied food products turbidity is determined by the
formula:
(3)
Where: S - jellied
food products turbidity; ksample–
is the conversion coefficient, which is equal to FNU (formazine Nephelometric
Unit) - 162,43 FNU, mm.
The
proposed method of determining the transparency of jellied fish products
contributes to the improvement of methods of a comprehensive assessment of the
quality and storage period of jellied food products and its semi-manufactures
in correlation depending on the intensity of the light flow, the functional and
technological properties of the product.